Manufacturer: SUN
Type: Vented Counterbalance Valve
Model: CWEG LGV
Capacity: 30 gpm
Pilot Ratio: 5:1
Maximum pressure: 6000 psi
Factory Pressure Settings Established at: 2 in³/min
Maximum Valve Leakage at Reseat: 5 drops/min
Check Cracking Pressure: 25 psi
Adjustment – No. of CCW Turns from Min. to Max. Setting: 5
Valve Hex Size: 1 1/8 in.
Adjustment Screw Internal Hex Size: 5/32 in.
Locknut Hex Size: 9/16 in.
Locknut Torque: 80 – 90 lbf in.
Valve Installation Torque: 45 – 50 lbf ft
Cartridge Thread: 1″-14 UNS