Honeywell EC7850 A 1122 4 Burner Controller

In stock1 unitReady to ship

444,44$

Burner Control

The Honeywell EC7850 A 1122 4 ensures reliable burner operation and flame monitoring with interchangeable flame amplifiers, five-function Run/Test switch, and broad voltage compatibility. Ideal for industrial combustion systems and heating controls.

Manufacturer
HONEYWELL
SKU
1057698
Condition
Used
Share
Massive Inventory
Global Shipping
Expert Support
Quality Guaranteed

Honeywell EC7850 A 1122 4 Burner Control

The Honeywell EC7850 A 1122 4 is a versatile and high-reliability burner control unit engineered for advanced combustion management and safety. Designed with a five-function Run/Test switch and interchangeable plug-in flame amplifiers, it ensures precise burner operation and easy maintenance. Suitable for industrial and commercial heating systems requiring stable flame supervision and multiple control interlocks.

Manufacturer: Honeywell

Type: Burner Control

Model: EC7850 A 1122 4

DesignFive-function Run/Test Switch / Interchangeable plug-in flame amplifiers
Maximum Total Connected Load2000 VA
Fusing (Total Connected Load)5 A “ 25 A (MAX. 20 A)
Alarm (Normally Open)AL “ 220/230/240 Vac, 1A, 10A inrush for 5000 cycles
Line Supply Voltage (L1)220-240 Vac (+10% / -15%), 50/60 Hz (±10%)
FAN “ Burner/Blower Motor220/230/240 Vac, 4A at PF = 0.5, 20A inrush
RT “ Limits and Burner Control220/230/240 Vac, 5A (maximum)
LD2 “ Airflow Switch Input220/230/240 Vac, 1 mA
PV1 “ Pilot Valve 1 (Interrupted)220/230/240 Vac, 4A at PF = 0.5, 20A inrush
MV “ Main Fuel Valve220/230/240 Vac, 4A at PF = 0.5, 20A inrush
IGN “ Ignition220/230/240 Vac, 4A at PF = 0.2
F “ Flame Signal136 to 220 Vac, current limited
HI “ Firing Rate High Fire220/230/240 Vac, 0.5A at PF = 0.5
COM “ Firing Rate Common220/230/240 Vac, 0.5A at PF = 0.5
MOD “ Firing Rate Modulate220/230/240 Vac, 0.5A at PF = 0.5
LO “ Firing Rate Low Fire220/230/240 Vac, 0.5A at PF = 0.5
Control Voltage230 Vac (+10% / -15%)
ES2 “ Preignition Interlock Input220/230/240 Vac, 1 mA
ES1 “ Low Fire Switch Input220/230/240 Vac, 1 mA
ES3 “ High Fire Switch Input220/230/240 Vac, 1 mA
LOS “ Lockout Input220/230/240 Vac, 1 mA
PV2 “ Pilot Valve 2 (Intermittent)220/230/240 Vac, 4A at PF = 0.5, 20A inrush
SHTR “ ShutterShutter drive for dynamic self-check flame sensor
Operating Temperature-40 °C to 60 °C
First Safety Time3 or 5 sec

More From HONEYWELL

Honeywell C6097A4210 GAS Pressure Switch
New

HONEYWELL

Honeywell C6097A4210 GAS Pressure Switch

SKU: 1102243

Qty: 2

99,99$
Honeywell D06F-11/2A Pressure Reducing Valve
New

HONEYWELL

Honeywell D06F-11/2A Pressure Reducing Valve

SKU: 1102269

Qty: 1

244,44$
Honeywell C7027A 1049 Ultraviolet Flame Sensor
New

HONEYWELL

Honeywell C7027A 1049 Ultraviolet Flame Sensor

SKU: 1097744

Qty: 2

299,99$
Honeywell M6284D1026 Modutrol IV Asymmetrical Motor
Used

HONEYWELL

Honeywell M6284D1026 Modutrol IV Asymmetrical Motor

SKU: 1092465

Qty: 1

Available through quotation
Honeywell L4097B1635 Leak-Safe Limit Control
New

HONEYWELL

Honeywell L4097B1635 Leak-Safe Limit Control

SKU: 1095796

Qty: 1

Available through quotation

Related Products

SCE E86-C Screen Printing Console
Used

SCE E86-C Screen Printing Console

SKU: 984074

Qty: 4

Available through quotation
RHP 7006E Tsum P4 Angular Contact Ball Bearing
New

RHP 7006E Tsum P4 Angular Contact Ball Bearing

SKU: 995338

Qty: 2

Available through quotation
Pilz C-P8-ZT Timer Module
Used

Pilz C-P8-ZT Timer Module

SKU: 984131

Qty: 1

Available through quotation
ABB CM-MSS Thermistor Motor Protection Monitoring Relay
NewAvailable on request

ABB CM-MSS Thermistor Motor Protection Monitoring Relay

SKU: 967587

Available on request

Available through quotation
Camozzi G7K Solenoid Coil
New

Camozzi G7K Solenoid Coil

SKU: 971329

Qty: 5

Available through quotation
Platinum International
Surplus, New & Used - Always Reliable
HONEYWELL SKU: 1057698
Honeywell EC7850 A 1122 4 Burner Controller
Honeywell EC7850 A 1122 4 Burner Controller
Price444,44$
Stock1 In stock
ManufacturerHONEYWELL
CategoryControl Units
ConditionUsed
SKU1057698

Burner Control

The Honeywell EC7850 A 1122 4 ensures reliable burner operation and flame monitoring with interchangeable flame amplifiers, five-function Run/Test switch, and broad voltage compatibility. Ideal for industrial combustion systems and heating controls.

Description
DesignFive-function Run/Test Switch / Interchangeable plug-in flame amplifiers
Maximum Total Connected Load2000 VA
Fusing (Total Connected Load)5 A “ 25 A (MAX. 20 A)
Alarm (Normally Open)AL “ 220/230/240 Vac, 1A, 10A inrush for 5000 cycles
Line Supply Voltage (L1)220-240 Vac (+10% / -15%), 50/60 Hz (±10%)
FAN “ Burner/Blower Motor220/230/240 Vac, 4A at PF = 0.5, 20A inrush
RT “ Limits and Burner Control220/230/240 Vac, 5A (maximum)
LD2 “ Airflow Switch Input220/230/240 Vac, 1 mA
PV1 “ Pilot Valve 1 (Interrupted)220/230/240 Vac, 4A at PF = 0.5, 20A inrush
MV “ Main Fuel Valve220/230/240 Vac, 4A at PF = 0.5, 20A inrush
IGN “ Ignition220/230/240 Vac, 4A at PF = 0.2
F “ Flame Signal136 to 220 Vac, current limited
HI “ Firing Rate High Fire220/230/240 Vac, 0.5A at PF = 0.5
COM “ Firing Rate Common220/230/240 Vac, 0.5A at PF = 0.5
MOD “ Firing Rate Modulate220/230/240 Vac, 0.5A at PF = 0.5
LO “ Firing Rate Low Fire220/230/240 Vac, 0.5A at PF = 0.5
Control Voltage230 Vac (+10% / -15%)
ES2 “ Preignition Interlock Input220/230/240 Vac, 1 mA
ES1 “ Low Fire Switch Input220/230/240 Vac, 1 mA
ES3 “ High Fire Switch Input220/230/240 Vac, 1 mA
LOS “ Lockout Input220/230/240 Vac, 1 mA
PV2 “ Pilot Valve 2 (Intermittent)220/230/240 Vac, 4A at PF = 0.5, 20A inrush
SHTR “ ShutterShutter drive for dynamic self-check flame sensor
Operating Temperature-40 °C to 60 °C
First Safety Time3 or 5 sec
Technical Specifications
Weight0,88 kg
ConditionUsed
ManufacturerHONEYWELL
Type of ProductBurner Control
Shelf No.251031