Schneider LC1D50ABD Contactor
Контактор Schneider Electric LC1D50ABD на 3 полюса из серии TeSys Deca с управлением 24 В DC, рабочим напряжением до 690 В AC и высокой производительностью управления двигателем для промышленных применений.
Schneider Electric LC1D50ABD Contactor
The Schneider Electric LC1D50ABD is a high-performance 3-pole contactor from the TeSys Deca range, engineered for motor control and resistive load applications. Designed for reliability and durability, it supports demanding industrial environments with high making and breaking capacities.
Manufacturer: Schneider Electric
Type: Contactor
Model: LC1D50ABD
Part No.: 940878
Serial No.: 3 389119 408783
Code: 2F 22243 / LC1D50ABD-B
Range: TeSys, TeSys Deca
Product Range: TeSys Deca
Device Short Name: LC1D
Contactor Application: Resistive Load, Motor Control
Poles Description: 3P
Pole Contact Composition: 3 NO
Auxiliary Contact Composition: 1 NO + 1 NC
Compatibility Code: LC1D
Protective Cover: With
[Ue] Rated Operational Voltage:
Motor Power (kW):
15 kW at 220/230 V AC 50/60 Hz (AC-3)
22 kW at 380/400 V AC 50/60 Hz (AC-3)
Motor Power (hp):
40 hp at 460/480 V AC 50/60 Hz for 3-phase motors
40 hp at 575/600 V AC 50/60 Hz for 3-phase motors
[Ith] Conventional Free Air Thermal Current:
10 A at 60 °C for signalling circuit
80 A at 60 °C for power circuit
Irms Rated Making Capacity:
140 A AC for signalling circuit (IEC 60947-5-1)
250 A DC for signalling circuit (IEC 60947-5-1)
900 A at 440 V for power circuit (IEC 60947)
Rated Breaking Capacity:
900 A at 440 V for power circuit (IEC 60947)
[Ui] Rated Insulation Voltage:
Safety Reliability Level:
B10d = 1,369,863 cycles (EN/ISO 13849-1, nominal load)
B10d = 20,000,000 cycles (EN/ISO 13849-1, mechanical load)
Operating Time:
50 ±15 % ms closing
16...24 ms opening
Dimensions:
| Power Circuit | ‰¤ 690 V AC 25...400 Hz |
| Power Circuit | ‰¤ 300 V DC |
| [Uc] Control Circuit Voltage | 24 V DC |
| Power Circuit | 600 V CSA Certified |
| Power Circuit | 600 V UL Certified |
| Power Circuit | 690 V (IEC 60947-4-1) |
| Signalling Circuit | 690 V (IEC 60947-1) |
| Signalling Circuit | 600 V CSA Certified |
| Signalling Circuit | 600 V UL Certified |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV (IEC 60947) |
| Inrush Power | 19 W at 20 °C |
| Hold-In Power Consumption | 7.4 W at 20 °C |
| Time Constant | 34 ms |
| Maximum Operating Rate | 3600 cycles/hour at 60 °C |
| Operating Altitude | 0...3000 m |
| Height | 122 mm |
| Width | 55 mm |
| Depth | 120 mm |