Skip to content
Panier & Devis
Accès direct sans ouvrir le menu
Thème
Choisissez clair, sombre ou système

Festo 8000810 8-VALVE Manifold

En stock1 unitéPrêt à être expédié

Valve Manifold High-performance FESTO 8 valve manifold with integrated pneumatic control, system supply, and PROFINET communication interface for advanced industrial automation applications.

Fabricant
FESTO
SKU
1102004
Condition
Nouveau
Partager
Stock massif
Expédition mondiale
Support Expert
Qualité garantie
Art. No.8000810
FluidCompressed Air
Actuation TypeElectrically
Structural DesignPiston Gate Valve
Sealing PrincipleSoft
Type Of ControlPilot-Controlled
Valve Size15 mm
Pilot Air Supply PortExternal/Internal
Operating Pressure-0.1 ... 0.7 MPa / -1 ... 7 bar
Pilot pressure1.5 ... 7 bar
Normal Nominal Flow Rate470 ... 690 l/min
Nominal Operating Voltage24 V DC
Valve Positions No.32
Pressure Zones No.16
Port SizeG 1/8
Seals MaterialHNBR/NBR
Protection ClassIP40 / IP65
Ambient Temperature-5 ... 50 °C
Attachment 1FESTO 8129261 SYSTEM SUPPLY
System Supply ManufacturerFESTO
Attachment 1 TypeSystem Supply
System Supply ModelCPX-AP-A-S-2-M12-5P
System Supply Art. No.8129261
System Supply Operating Voltage24 V DC
System Supply Nominal Current16 A
System Supply Connection TypeM12x1, L-Coded 5-Pin
System Supply Housing MaterialPA-Reinforced
System Supply Ambient Temperature-20 ... 50 °C
System Supply Dimensions50.1 x 150 x 45.6 mm
Attachment 2FESTO 8129241 PROFINET INTERFACE
PROFINET Interface ManufacturerFESTO
Attachment 2 TypePROFINET Interface
PROFINET Interface ModelCPX-AP-A-PN-M12
PROFINET Interface Art. No.8129241
PROFINET Interface MAC-ID00-OE-FO-9A-5D-AB
PROFINET Interface Diagnostics Via LEDDiagnostics Per Module / PROFINET Communication / Power Supply for Electronics/Sensors / Load Power Supply / System Diagnostics / Maintenance Required
PROFINET Interface Diagnostics Via BusAPDD Invalid / Load Switch-Off / Communication Error / Electronics/Sensors Overvoltage / Load Overvoltage / Electronics/Sensors Undervoltage / Load Undervoltage
PROFINET Interface Fieldbus Interface, TypeEthernet
PROFINET Interface Fieldbus Interface, ProtocolLLDP / MRP, MRPD (Ring Redundancy) / PROFINET FSU / PROFINET I&M0..3 / PROFINET IRT / PROFINET RT / PROFINET Shared Device / S2 System Redundancy / SNMP
PROFINET Interface Transmission Rate100 Mbit/s
PROFINET Interface Address Capacity Inputs Max.1024 byte
PROFINET Interface Address Capacity Outputs Max.1024 byte
PROFINET Interface Operating Voltage24 V DC
PROFINET Interface Current Consumption80 mA
PROFINET Interface MaterialPBT-Reinforced
PROFINET Interface Ambient Temperature-20 ... 50 °C
PROFINET Interface Dimensions50.1 x 107.3 x 57.5 mm
Stock KeyJO-004
ConditionNew
SKU1102004
Weight1,20
Festo 15040 H708 Cartridge Cylinder
Nouveau

FESTO

Festo 15040 H708 Cartridge Cylinder

SKU: 1103264

Qté: 4

Disponible sur devis
Festo 536292 Compact Cylinder
Utilisé

FESTO

Festo 536292 Compact Cylinder

SKU: 1103274

Qté: 20

Disponible sur devis
Festo 153068 Push-IN L-Connector
Nouveau

FESTO

Festo 153068 Push-IN L-Connector

SKU: 1103325

Qté: 37

Disponible sur devis
Festo 156947 Compact Cylinder
NouveauDisponible sur demande

FESTO

Festo 156947 Compact Cylinder

SKU: 1103229

Disponible sur demande

Disponible sur devis
Festo 531668 Quick Coupling Plug
Nouveau

FESTO

Festo 531668 Quick Coupling Plug

SKU: 1103321

Qté: 1

Disponible sur devis
Univer BE-5150 Pneumatic Valve
Nouveau

UNIVER ?

Univer BE-5150 Pneumatic Valve

SKU: 1053441

Qté: 1

Disponible sur devis
Rexroth DR 10-5-32/315YM Pilot Operated Pressure Reducing Valve
Utilisé

REXROTH

Rexroth DR 10-5-32/315YM Pilot Operated Pressure Reducing Valve

SKU: 984090

Qté: 2

Disponible sur devis
MAC 166B-611JM Solenoid Pilot Operated Valve
Utilisé

MAC 166B-611JM Solenoid Pilot Operated Valve

SKU: 971228

Qté: 1

50,00$
Rexroth DR 30 2-31/100Y Pilot Operated Pressure Reducing Valve
Utilisé

REXROTH

Rexroth DR 30 2-31/100Y Pilot Operated Pressure Reducing Valve

SKU: 988678

Qté: 1

Disponible sur devis
GSR .242 Solenoid Coil
Nouveau

GSR .242 Solenoid Coil

SKU: 971255

Qté: 4

Disponible sur devis
Platinum International
Surplus, Neuf & D'occasion - Toujours Fiable
FESTO SKU: 1102004
Festo 8000810 8-VALVE Manifold
Festo 8000810 8-VALVE Manifold
PrixSur demande
Stock1 En stock
FabricantFESTO
CatégoriePneumatic Valves
ConditionNouveau
SKU1102004
Valve Manifold High-performance FESTO 8 valve manifold with integrated pneumatic control, system supply, and PROFINET communication interface for advanced industrial automation applications.
Description
Art. No.8000810
FluidCompressed Air
Actuation TypeElectrically
Structural DesignPiston Gate Valve
Sealing PrincipleSoft
Type Of ControlPilot-Controlled
Valve Size15 mm
Pilot Air Supply PortExternal/Internal
Operating Pressure-0.1 ... 0.7 MPa / -1 ... 7 bar
Pilot pressure1.5 ... 7 bar
Normal Nominal Flow Rate470 ... 690 l/min
Nominal Operating Voltage24 V DC
Valve Positions No.32
Pressure Zones No.16
Port SizeG 1/8
Seals MaterialHNBR/NBR
Protection ClassIP40 / IP65
Ambient Temperature-5 ... 50 °C
Attachment 1FESTO 8129261 SYSTEM SUPPLY
System Supply ManufacturerFESTO
Attachment 1 TypeSystem Supply
System Supply ModelCPX-AP-A-S-2-M12-5P
System Supply Art. No.8129261
System Supply Operating Voltage24 V DC
System Supply Nominal Current16 A
System Supply Connection TypeM12x1, L-Coded 5-Pin
System Supply Housing MaterialPA-Reinforced
System Supply Ambient Temperature-20 ... 50 °C
System Supply Dimensions50.1 x 150 x 45.6 mm
Attachment 2FESTO 8129241 PROFINET INTERFACE
PROFINET Interface ManufacturerFESTO
Attachment 2 TypePROFINET Interface
PROFINET Interface ModelCPX-AP-A-PN-M12
PROFINET Interface Art. No.8129241
PROFINET Interface MAC-ID00-OE-FO-9A-5D-AB
PROFINET Interface Diagnostics Via LEDDiagnostics Per Module / PROFINET Communication / Power Supply for Electronics/Sensors / Load Power Supply / System Diagnostics / Maintenance Required
PROFINET Interface Diagnostics Via BusAPDD Invalid / Load Switch-Off / Communication Error / Electronics/Sensors Overvoltage / Load Overvoltage / Electronics/Sensors Undervoltage / Load Undervoltage
PROFINET Interface Fieldbus Interface, TypeEthernet
PROFINET Interface Fieldbus Interface, ProtocolLLDP / MRP, MRPD (Ring Redundancy) / PROFINET FSU / PROFINET I&M0..3 / PROFINET IRT / PROFINET RT / PROFINET Shared Device / S2 System Redundancy / SNMP
PROFINET Interface Transmission Rate100 Mbit/s
PROFINET Interface Address Capacity Inputs Max.1024 byte
PROFINET Interface Address Capacity Outputs Max.1024 byte
PROFINET Interface Operating Voltage24 V DC
PROFINET Interface Current Consumption80 mA
PROFINET Interface MaterialPBT-Reinforced
PROFINET Interface Ambient Temperature-20 ... 50 °C
PROFINET Interface Dimensions50.1 x 107.3 x 57.5 mm
Stock KeyJO-004
ConditionNew
SKU1102004
Weight1,20
Spécifications techniques
Weight1,2 kg
ManufacturerFESTO
Type of Product8 Valve Manifold
ModelVTUX-A-P-APA-SF-US8XX-XL8AXR70E-PNQB-X
Shelf No.260524