Skip to content
Panier & Devis
Accès direct sans ouvrir le menu
Thème
Choisissez clair, sombre ou système

West MLC9000+Z4660 Single Loop Controller Module

En stock1 unitéPrêt à être expédié

Single Loop Controller Module

WEST MLC9000+Z4660 single loop controller supporting thermocouple, RTD, and DC linear inputs, designed for precise temperature and process control in industrial applications.

Fabricant
WEST
SKU
1091334
Catégorie
PLC Modules
Condition
Nouveau
Partager
Stock massif
Expédition mondiale
Support Expert
Qualité garantie

WEST MLC9000+Z4660 Single Loop Controller Module

The WEST MLC9000Z4660 is a versatile single loop controller module designed for precise temperature and process control applications. It supports a wide range of sensor inputs and control outputs, making it suitable for industrial automation, thermal processes, and DC signal control systems.

Manufacturer: WEST

Type: Single Loop Controller Module

Model: MLC9000+Z4660

Part No.: C412.00.016.041 / HL3 1223 313859

FunctionOne loop temperature or DC process input, type and scale user selectable
Thermocouple InputsB, N, J, R, K, S, L, T
Thermocouple Range-240 / 1759°C (-400 / 3198°F), dependent on T/C type
RTD Inputs3-Wire PT100, NI120
RTD Range-199.9 / 800.3°C (-327.3 / 1472.5°F)
DC Linear Inputs0“20 mA, 4“20 mA, 0“50 mV, 10“50 mV, 0“5 V, 1“5 V, 0“10 V, 2“10 V
DC Linear Scale-32000 / 32000
Input Sample Rate10 Hz (100 msec)
Sensor Break DetectionDetected within two seconds; control outputs turn off (0% power); alarms activate except heater break alarms
Heater Break Alarm FunctionOptional; monitors heater current for high, low, or short circuit conditions
Heater Current Input0 / 50 mA, 0 / 60 mA sinusoidal RMS from current transformer
Heater Current Scaling0.1 / 1000 AAC
Relay OutputsSPST contact
Relay Rating2 A resistive @ 120 / 240 VAC
SSR Driver Outputs12 VDC nominal (10 V minimum), up to 20 mA
SSR IsolationIsolated from process input and relay outputs; not isolated from similar or linear outputs in the same system
Linear OutputAvailable only on 3-output models
Linear Output Resolution8 bits in 250 msec, 10 bits in 1 second (typical)
Ambient Temperature0 / 55 °C
Dimensions100 x 22 x 120 mm
Hawe GZ3-0R Solenoid Operated Directional Seated Valve
UtiliséDisponible sur demande

Hawe GZ3-0R Solenoid Operated Directional Seated Valve

SKU: 974576

Disponible sur demande

150,00$
SKF 62206-2RS1 Deep Groove Ball Bearing
Nouveau

SKF?

SKF 62206-2RS1 Deep Groove Ball Bearing

SKU: 989294

Qté: 3

Disponible sur devis
Schmersal AZR31T2 Safety Controller
Nouveau

Schmersal AZR31T2 Safety Controller

SKU: 1001148

Qté: 1

Disponible sur devis
Hawe W S2-2 Solenoid Operated Directional Seated Valve
Utilisé

Hawe W S2-2 Solenoid Operated Directional Seated Valve

SKU: 974600

Qté: 1

145,00$
+GF+ PV94 Pa/Fb Pressure Valve
NouveauDisponible sur demande

+GF+ PV94 Pa/Fb Pressure Valve

SKU: 971212

Disponible sur demande

80,00$
Platinum International
Surplus, Neuf & D'occasion - Toujours Fiable
WEST SKU: 1091334
West MLC9000+Z4660 Single Loop Controller Module
West MLC9000+Z4660 Single Loop Controller Module
PrixSur demande
Stock1 En stock
FabricantWEST
CatégoriePLC Modules
ConditionNouveau
SKU1091334

Single Loop Controller Module

WEST MLC9000+Z4660 single loop controller supporting thermocouple, RTD, and DC linear inputs, designed for precise temperature and process control in industrial applications.

Description

FunctionOne loop temperature or DC process input, type and scale user selectable
Thermocouple InputsB, N, J, R, K, S, L, T
Thermocouple Range-240 / 1759°C (-400 / 3198°F), dependent on T/C type
RTD Inputs3-Wire PT100, NI120
RTD Range-199.9 / 800.3°C (-327.3 / 1472.5°F)
DC Linear Inputs0“20 mA, 4“20 mA, 0“50 mV, 10“50 mV, 0“5 V, 1“5 V, 0“10 V, 2“10 V
DC Linear Scale-32000 / 32000
Input Sample Rate10 Hz (100 msec)
Sensor Break DetectionDetected within two seconds; control outputs turn off (0% power); alarms activate except heater break alarms
Heater Break Alarm FunctionOptional; monitors heater current for high, low, or short circuit conditions
Heater Current Input0 / 50 mA, 0 / 60 mA sinusoidal RMS from current transformer
Heater Current Scaling0.1 / 1000 AAC
Relay OutputsSPST contact
Relay Rating2 A resistive @ 120 / 240 VAC
SSR Driver Outputs12 VDC nominal (10 V minimum), up to 20 mA
SSR IsolationIsolated from process input and relay outputs; not isolated from similar or linear outputs in the same system
Linear OutputAvailable only on 3-output models
Linear Output Resolution8 bits in 250 msec, 10 bits in 1 second (typical)
Ambient Temperature0 / 55 °C
Dimensions100 x 22 x 120 mm

Spécifications techniques

Weight0,19 kg
ConditionNew
ManufacturerWEST
Type of ProductSingle Loop Controller Module
Shelf No.260324