Sensor for Mass Flow with Heating Jacket

The KROHNE OPTIMASS 1400C S15 provides accurate mass flow measurement with HART communication, stainless-steel construction, IP66/IP67 protection, and optional heating jacket for operation up to 130 °C.

Fabricante
KROHNE
SKU
1084019
Condição
Novo
Compartilhar
Grande Estoque
Envio Global
Suporte Especializado
Qualidade Garantida

KROHNE OPTIMASS 1400C S15 Sensor for Mass Flow with Heating Jacket

The KROHNE OPTIMASS 1400C S15 is a high-precision mass flow sensor equipped with an integrated heating jacket for stable operation under varying process conditions. Designed with durable stainless-steel materials, it provides accurate flow measurement of liquids such as water across a wide temperature and pressure range. This model combines reliability, precision, and robust construction for demanding industrial environments.

Manufacturer: KROHNE

Type: Sensor for Mass Flow with Heating Jacket

Model: OPTIMASS 1400C S15

Serial Number: G220000008310750

Code: 13218-P, CG430814A8, VE5444106200106A8000010, VE834S0MD0G200000006000

Electronics Revision: ER2.1.5_

Heating Jacket (Accessory)

Calibration FluidWater
Maximum Temperature Difference80 °C
Communication ProtocolHART
Power Supply12 to 24 VDC
Power Consumption12 W
Wetted Materials316L Stainless Steel and Duplex 22Cr
Protection ClassIP66 / IP67
ConnectionNPT
Primary Pressure Rating“1 to 15.3 barg (“40 to 130 °C)
Alternate Pressure Rating“1 to 19 barg (“40 to 20 °C)
Operating Temperature Range (Primary)“40 °C to +130 °C
Calibration Temperature+20 °C
Calibration Pressure1 to 6 barg
Flanged Connection Temperature Range“40 °C to +130 °C
Hygienic Connection Temperature Range“40 °C to +130 °C
Nominal Pressure at 20 °C“1 to 100 barg (FM / PED)
ComplianceCRN / ASME B31.3: “1 to 100 barg
Connection OptionsNPT
Maximum Pressure10 bar
Maximum Temperature130 °C
Krohne VF11.XXGAVXPC Vibrating Level Switch
Novo

KROHNE

Krohne VF11.XXGAVXPC Vibrating Level Switch

SKU: 1074869

Qtd: 1

Disponível mediante cotação
Krohne Optibar PM 3050 Level AND Pressure Measurement
Novo

KROHNE

Krohne Optibar PM 3050 Level AND Pressure Measurement

SKU: 1083060

Qtd: 1

Disponível mediante cotação
Krohne TT 51 C Temperature Transmitter Head
Novo

KROHNE

Krohne TT 51 C Temperature Transmitter Head

SKU: 1079610

Qtd: 1

Disponível mediante cotação
Krohne CG300116AE Flowmeter Signal Converter
Usado

KROHNE

Krohne CG300116AE Flowmeter Signal Converter

SKU: 1044102

Qtd: 5

599,99$
Krohne D6 Holland Altometer
Usado

KROHNE

Krohne D6 Holland Altometer

SKU: 2005419

Qtd: 1

1 299,99$

Produtos Relacionados

Rexroth DR 10-5-32/315YM Pilot Operated Pressure Reducing Valve
Usado

REXROTH

Rexroth DR 10-5-32/315YM Pilot Operated Pressure Reducing Valve

SKU: 984090

Qtd: 2

Disponível mediante cotação
Siemens 6ES5 470-8MA12 Analog Output
Usado

SIEMENS

Siemens 6ES5 470-8MA12 Analog Output

SKU: 995271

Qtd: 1

22,22$
YIHAO YH 5um / 2200 LINEAR GRATING RULER
NovoDisponível sob consulta

YIHAO

YIHAO YH 5um / 2200 LINEAR GRATING RULER

SKU: 980402

Disponível sob consulta

Disponível mediante cotação
SKF 62206-2RS1 Deep Groove Ball Bearing
Novo

SKF 62206-2RS1 Deep Groove Ball Bearing

SKU: 989294

Qtd: 3

Disponível mediante cotação
Moeller PKZM0-0,4 Motor-Protective Circuit-Breaker
Novo

MOELLER

Moeller PKZM0-0,4 Motor-Protective Circuit-Breaker

SKU: 1003533

Qtd: 17

Disponível mediante cotação
Platinum International
Excedente, Novos & Usados - Sempre Confiáveis
KROHNE SKU: 1084019
Krohne Optimass 1400C S15 Mass Flow Sensor
Krohne Optimass 1400C S15 Mass Flow Sensor
Preço1 499,99$
Estoque1 Em estoque
FabricanteKROHNE
CategoriaOther Mechanical Equipment
CondiçãoNovo
SKU1084019

Sensor for Mass Flow with Heating Jacket

The KROHNE OPTIMASS 1400C S15 provides accurate mass flow measurement with HART communication, stainless-steel construction, IP66/IP67 protection, and optional heating jacket for operation up to 130 °C.

Descrição

Calibration FluidWater
Maximum Temperature Difference80 °C
Communication ProtocolHART
Power Supply12 to 24 VDC
Power Consumption12 W
Wetted Materials316L Stainless Steel and Duplex 22Cr
Protection ClassIP66 / IP67
ConnectionNPT
Primary Pressure Rating“1 to 15.3 barg (“40 to 130 °C)
Alternate Pressure Rating“1 to 19 barg (“40 to 20 °C)
Operating Temperature Range (Primary)“40 °C to +130 °C
Calibration Temperature+20 °C
Calibration Pressure1 to 6 barg
Flanged Connection Temperature Range“40 °C to +130 °C
Hygienic Connection Temperature Range“40 °C to +130 °C
Nominal Pressure at 20 °C“1 to 100 barg (FM / PED)
ComplianceCRN / ASME B31.3: “1 to 100 barg
Connection OptionsNPT
Maximum Pressure10 bar
Maximum Temperature130 °C

Especificações Técnicas

Weight22 kg
ConditionNew
ManufacturerKROHNE
Shelf No.251103
Type of ProductMASS FLOW SENSOR
ModelOPTIMASS 1000 / 2000