Skip to content
Panier & Devis
Accès direct sans ouvrir le menu
Thème
Choisissez clair, sombre ou système

Sick LFP0400-A4NMB TDR Level Sensor

En stock1 unitéPrêt à être expédié

666,66$

TDR Level Sensor The SICK LFP0400-A4NMB is a TDR level sensor with a 400 mm rod probe, IO-Link, analog and switching outputs, designed for reliable fluid level measurement in industrial applications.

Fabricant
SICK
SKU
1100996
Catégorie
Transmitter
Condition
Nouveau
Partager
Stock massif
Expédition mondiale
Support Expert
Qualité garantie
Part No.1057075
Ref No1805 0103
SeriesLFP Cubic
MediumFluids
MeasurementSwitch, Continuous Design Standard
Probe typeRod probe
Probe length400 mm
Process pressure–1 bar ... 10 bar
Process temperature–20 °C ... +100 °C
Accuracy of sensor element± 5 mm
Reproducibility2 mm
Resolution2 mm
Response time400 ms
Maximum level change500 mm/s
Deactivated area at process connection25 mm
Supply voltage12 V DC ... 30 V DC
Power consumption100 mA at 24 V DC without output load
Initialization time5 s
Protection classIII
Connection typeRound connector M12 x 1, 5-pin
Output signal1 x PNP + 1 x PNP/NPN + 4 mA ... 20 mA / 0 V ... 10 V
Switching outputIO-Link, 1 x PNP + 1 x PNP/NPN
Output load4 mA ... 20 mA < 500 Ohm at Uv > 15 V, 4 mA ... 20 mA < 350 Ohm at Uv > 12 V, 0 V ... 10 V > 750 Ohm at Uv 14 = V
HysteresisMin. 2 mm, free adjustable
Output current100 mA
Inductive load1 H
Capacitive load100 nF
Enclosure rating IP67EN 60529
Temperature drift0.1 mm/K
Lower signal level3.8 mA ... 4 mA
Upper signal level20 mA ... 20.5 mA
EMCEN 61326-2-3, 2014/30/EU
Wetted parts1.4404, PTFE, FKM
Process connectionG ¾ A
Housing materialPlastic PBT
Max. probe load6 Nm
Stock keyCON003
ConditionNew
SKU1100996
Weight0,47
SICK	WL100L-F2131 Photoelectric Retro-Reflective Sensor
Nouveau

SICK

SICK WL100L-F2131 Photoelectric Retro-Reflective Sensor

SKU: 1100993

Qté: 1

Disponible sur devis
Sick LMS500-21000 High Resolution Laser Scanner Sensor
Utilisé

SICK

Sick LMS500-21000 High Resolution Laser Scanner Sensor

SKU: 1104119

Qté: 1

499,99$
Sick LMS200-30106 Laser Scanner Sensor
Utilisé

SICK

Sick LMS200-30106 Laser Scanner Sensor

SKU: 1104118

Qté: 1

444,44$
Sick AFM60B-TGRK000S14 Absolute Encoder
Utilisé

SICK

Sick AFM60B-TGRK000S14 Absolute Encoder

SKU: 1093953

Qté: 1

Disponible sur devis
Sick LFP0332-A4NMBS08 TDR Level Sensor
Nouveau

SICK

Sick LFP0332-A4NMBS08 TDR Level Sensor

SKU: 1100997

Qté: 2

666,66$
UWT Rotonivo RN3001 WGSG29 LGS29B Rotary Paddle Level Switch
Utilisé

UWT

UWT Rotonivo RN3001 WGSG29 LGS29B Rotary Paddle Level Switch

SKU: 1008316

Qté: 1

390,00$
Krohne Optitemp TCA-F 23 Temperature Transmitter
Nouveau

KROHNE

Krohne Optitemp TCA-F 23 Temperature Transmitter

SKU: 1083057

Qté: 4

Disponible sur devis
United Electric Controls H402 555 Differential Pressure Switch
Utilisé

UNITED ELECTRIC CONTROLS

United Electric Controls H402 555 Differential Pressure Switch

SKU: 1034820

Qté: 2

Disponible sur devis
Endress-Hauser EC 17 Z Capacitance Limit Detection Electronic Insert
Utilisé

Endress-Hauser

Endress-Hauser EC 17 Z Capacitance Limit Detection Electronic Insert

SKU: 1044794

Qté: 4

Disponible sur devis
Endress-Hauser EC 61 Z Capacitance Limit Detection Electronic Insert
Utilisé

Endress-Hauser

Endress-Hauser EC 61 Z Capacitance Limit Detection Electronic Insert

SKU: 1044796

Qté: 1

77,77$
Platinum International
Surplus, Neuf & D'occasion - Toujours Fiable
SICK SKU: 1100996
Sick LFP0400-A4NMB TDR Level Sensor
Sick LFP0400-A4NMB TDR Level Sensor
Prix666,66$
Stock1 En stock
FabricantSICK
CatégorieTransmitter
ConditionNouveau
SKU1100996
TDR Level Sensor The SICK LFP0400-A4NMB is a TDR level sensor with a 400 mm rod probe, IO-Link, analog and switching outputs, designed for reliable fluid level measurement in industrial applications.
Description
Part No.1057075
Ref No1805 0103
SeriesLFP Cubic
MediumFluids
MeasurementSwitch, Continuous Design Standard
Probe typeRod probe
Probe length400 mm
Process pressure–1 bar ... 10 bar
Process temperature–20 °C ... +100 °C
Accuracy of sensor element± 5 mm
Reproducibility2 mm
Resolution2 mm
Response time400 ms
Maximum level change500 mm/s
Deactivated area at process connection25 mm
Supply voltage12 V DC ... 30 V DC
Power consumption100 mA at 24 V DC without output load
Initialization time5 s
Protection classIII
Connection typeRound connector M12 x 1, 5-pin
Output signal1 x PNP + 1 x PNP/NPN + 4 mA ... 20 mA / 0 V ... 10 V
Switching outputIO-Link, 1 x PNP + 1 x PNP/NPN
Output load4 mA ... 20 mA < 500 Ohm at Uv > 15 V, 4 mA ... 20 mA < 350 Ohm at Uv > 12 V, 0 V ... 10 V > 750 Ohm at Uv 14 = V
HysteresisMin. 2 mm, free adjustable
Output current100 mA
Inductive load1 H
Capacitive load100 nF
Enclosure rating IP67EN 60529
Temperature drift0.1 mm/K
Lower signal level3.8 mA ... 4 mA
Upper signal level20 mA ... 20.5 mA
EMCEN 61326-2-3, 2014/30/EU
Wetted parts1.4404, PTFE, FKM
Process connectionG ¾ A
Housing materialPlastic PBT
Max. probe load6 Nm
Stock keyCON003
ConditionNew
SKU1100996
Weight0,47
Spécifications techniques
ManufacturerSICK
Type of ProductTDR LEVEL SENSOR
ModelLFP0400-A4NMB
Shelf No.260903
Weight0,47